工艺:点焊功能的使用(鱼鳞纹和间断)(中英)

点焊功能对应的面板监测页版本号为:330以上(含)

The version number of the panel monitoring page corresponding to the spot welding function is: 330 or above (inclusive)

一. 如何使用点焊功能

1.1 首页启用点焊模式

1.2 设置里面选择点焊的类型(鱼鳞纹/间断)

1.3 设置里面设置合理的点焊持续时间和点焊间隔时间

二.点焊类型的参数和调试

首先,使用连续焊接来调试好工艺,再去启用点焊功能选择点焊类型

I. How to use spot welding function



1.1 Home Enable spot welding mode


1.2 Select the type of spot welding inside the setting (fish scale/break)


1.3 Settings Set reasonable spot welding duration and spot welding interval


Two. Spot welding type parameters and debugging


First, use continuous welding to debug the process, and then select the spot welding type by enabling the spot welding function





2.1鱼鳞模式焊接

(在此模式下,间断时只关激光,其他设置的参数如开关/关光时间不影响也不生效)

只需设置点焊持续时间和间隔时间即可产生鱼鳞纹焊接效果,最低可设置1ms)

点焊持续时间:150ms(此参数影响焊接的纹状大小)

点焊间隔时间:50ms(此参数影响两个纹状之间的间隔)

2.1 Fish scale mode welding


(In this mode, only the laser is turned off during the interruption, and other parameters such as switching/switching time do not affect or take effect)


Just set the spot welding duration and interval time to produce fish scale welding effect, the minimum can be set 1ms)


case


Spot welding duration: 150ms (this parameter affects the grain size of the weld)


Spot welding interval time: 50ms (This parameter affects the interval between the two grooves)



2.2间断模式焊接

(在此模式下,间断时关激光、关保护气体、停止送丝。其他设置的参数如开关/关光时间影响也生效,。主要用于定长焊接

通过设置点焊持续时间来改变焊接长度,点焊间隔时间可设高一些

点焊持续时间:1000ms(此参数影响焊接长度,也就是出光的时间)

点焊间隔时间:5000ms(此参数可固定数值,默认为5000)

请注意,在此模式下,断丝的时候需要人为的判定,及时上抬断丝

2.2 Intermittent mode welding


In this mode, the laser is turned off, the protective gas is turned off, and the wire feed is stopped. Other parameters such as on/off light time are also affected. Mainly used for fixed length welding)


Change the welding length by setting the spot welding duration, and the spot welding interval can be set higher


case


Spot welding duration: 1000ms (this parameter affects the welding length, that is, the time of the light)


Spot welding interval: 5000ms (This parameter can be fixed, the default is 5000)


Please note that in this mode, human judgment is required to lift the broken wire in time




图示: