Welding joint problem: handling of each signal alarm具体表现: 首页出现报警无法使用,包括各类镜片/电机温度报警,水冷机/气压/激光器报警 Specific performance: The alarm on the home page cannot be used, including all kinds of lens/motor temperature alarm, water cooler/air pressure/laser alarm. 原因分析: 温度类报警一般是热敏没插好/损坏或镜片损坏,而水冷机/气压/激光器报警一般是设置的电平不对 Cause analysis: Generally, the temperature alarm means that the thermal sensor is not plugged in/damaged or the lens is damaged, while the alarm of water cooler/air pressure/laser is usually set at the wrong level. 故障处理 ①温度类:一般指镜片温度报警,通常先查看镜片是否损坏,更换受损的镜片,如镜片正常,则设置里面直接屏蔽此报警,设置内把对应的镜片温度报警阈值设置为0保存即可 ②电平类:一般指冷水机/气压/激光器报警 电平的报警逻辑,系统会根据你的接线方式与你的设置电平做对比,不同则报警,请注意:报警信号只接受无源的常开常闭信号,请勿输入电压 通常出现报警均为报警电平设置错误,更改对应的报警电平即可 如果在有接报警信号而出现报警,不管怎么更改均报警的情况,那就把报警信号拔掉并设置为低电平 Fault handling ① Temperature category: generally refers to the lens temperature alarm. Usually, first check whether the lens is damaged or not, and replace the damaged lens. If the lens is normal, the alarm is directly shielded in the setting, and the corresponding lens temperature alarm threshold is set to 0 in the setting to save. ② Level category: generally refers to water cooler/air pressure/laser alarm. The alarm logic of the level, the system will compare it with your set level according to your wiring mode, and alarm if it is different. Please note that the alarm signal only accepts passive normally open and normally closed signals, so please do not input voltage. Usually, the alarm is an alarm level setting error, so just change the corresponding alarm level. If there is an alarm when an alarm signal is connected, the alarm will be given no matter how it is changed, then unplug the alarm signal and set it to a low level. 信号接口一 1/2脚气压报警信号 信号接口一 3/4脚水冷机报警信号 信号接口三 1/4脚激光器报警信号 Signal interface-1/2 foot air pressure alarm signal Signal interface-alarm signal of 3/4 foot water cooler Signal interface 3 1/4 pin laser alarm signal |